University of Khartoum

Effect of Emitter Types, Operating Pressures and Treated Wastewater on the Hydraulic Performance of Drip Irrigation System Under Controlled Condition

Effect of Emitter Types, Operating Pressures and Treated Wastewater on the Hydraulic Performance of Drip Irrigation System Under Controlled Condition

Show simple item record

dc.contributor.advisor Ali Widaa Mohamed Elamin en_US
dc.contributor.author Hassan, Mohammed Elmostafa Hussain
dc.contributor.other Department of Agricultural Engineering en_US
dc.date 2015
dc.date.accessioned 2016-06-21T09:25:38Z
dc.date.available 2016-06-21T09:25:38Z
dc.date.submitted 2016-06-21
dc.identifier.uri http://khartoumspace.uofk.edu/123456789/22037
dc.description.abstract The experiment was carried out in the Faculty of Agriculture, University of Khartoum, during the period from May to September 2015. The objective of this study was to evaluate the hydraulic performance of drip irrigation system under controlled condition. The experimental work was held in laboratory, whereas a model for drip irrigation system used. The treatments consisted of three types of emitters (turbo, Octa and barrel) with three operating pressures (P1 (0.5), P2 (0.75) and P3 (1) bar). Treated wastewater with salinity 2.2 ds/m used as a source of water. The uniformity parameters (coefficient uniformity (CU%), emission uniformity (EU%), coefficient of variation (CV%)) and clogging percentage (Pclog) were studied. The operating pressure kept constant during the experiment for each treatment, SAS (statistical package) used to analyze the data the variations among means were checked by the least significant difference (LSD). The results showed that the Turbo pressure compensating emitter recoded significant differences (P ≤ 0.05) in increasing values of CU% and EU% compared with Octa and Barrel emitters, respectively. On the other hand, Octa and Turbo showed higher resistance to clogging phenomenon than Barrel, which recorded a high percentage of clogging. The uniformity parameters showed clear response to the operating pressures. Whereas, P3 gave the highest values of CU% and EU%, while P1 recorded the lowest values and vice versa results were recorded for CV% and clogging percentage. The conclusion of this study is that emitter types and operating pressures have profound effect on the hydraulic performance of drip irrigation system, Hence, they should be considered when dealing with drip irrigation system. en_US
dc.language.iso en en_US
dc.publisher University of Khartoum en_US
dc.subject Wastewater en_US
dc.subject Hydraulic Performance en_US
dc.subject Controlled Condition en_US
dc.title Effect of Emitter Types, Operating Pressures and Treated Wastewater on the Hydraulic Performance of Drip Irrigation System Under Controlled Condition en_US
dc.type Thesis en_US
dc.Degree M.Sc en_US
dc.Faculty Agriculture en_US
dc.description.arabic-abstract : أُجريت التجربة فى كلية الزراعة جامعة الخرطوم خلال الفترة من شهر مايو 2015 إلى شهر سبتمبر 2015. كان الهدف من هذه الدراسة هو تقييم الأداء الهيدروليكى لنظام الرى بالتنقيط تحت ظروف خاضعة للرقابة. نُفِذ العمل التجريبى فى المعمل باستخدم نموذج لنظام الرى بالتنقيط. شملت المعاملات ثلاثة أنواع من النقاطات، (تيربو، اوكتا، برميلى) وثلاث ضغوط تشغيل (P1)) 0.5 - P2)) 0.75 - P3)) 1 بار)، استخدمت مياه عادمة ذات ملوحة 2.2 ديسمينز/متر كمصدر للمياه. دُرِست عوامل التجانس (معامل الانتظامية (%CU), إنتظامية التوزيع (EU%), معامل الاختلاف (CV%) ونسبة الانسداد (Pclog)). كان الضغط التشغيلي ثابتا لكل معاملة خلال فترة التجربة. استخدمت الحزمة الاحصائية (SAS) لتحليل البيانات, وحسبت الاختلافات المعنوية بين المتوسطات باستخدام اقل فرق معنوى (LSD). حيث أظهرت النتائج ان النقاط تيربو قد سجل فروقات معنوية (P ≤ 0.05) لمعامل الإنتظامية (%CU) وإنتظامية التوزيع (EU%) مقارنة مع اوكتا والبرميلى على التوالى. من ناحية اخرى اظهرت النقاطات تيربو ، اوكتا أعلى مقاومة لظاهرة الانسداد مقارنة مع النوع البرميلى الذى سجل أعلى قيمة للانسداد. كما أظهرت المعاملات استجابة واضحة لضغوط التشغيل حيث سجل الضغط ( P3) أعلى قيم لمعامل الانتظامية (%CU) وإنتظامية التوزيع (EU%) فى حين سجل الضغط (P1) أدنى قيمة لهما, بينما كانت النتائج عكسية لمعامل الاختلاف (CV%) ونسبة الانسداد. خلصت هذه الدراسة إلى ان نوع النقاط وضغوطات التشغيل لها تاثير كبير على نظام الرى بالتنقيط, بالتالى ينبغى اعتمادهما عند التعامل مع هذا النظام. en_US

Files in this item

Files Size Format View

This item appears in the following Collection(s)

Show simple item record

Share

Search DSpace


Browse

My Account