Problems Affecting Condenser Performance in Dr. Sherief Power Station
Problems Affecting Condenser Performance in Dr. Sherief Power Station
No Thumbnail Available
Date
2015-05-05
Authors
Ali, Basil Hassan said
Journal Title
Journal ISSN
Volume Title
Publisher
UOFK
Abstract
The objective of this study is to investigate the problems affecting condenser
performance in Dr Sherief power station and to suggest a suitable solution for the
investigated problems.
To achieve the objective of the study the following procedure was applied:
• The design values of all parameters controlling condenser performance
equations were determined.
• Condenser performance charts were identified
• Deviations of the actual values from the design, and the reasons of
deviation were determined
• Suitable solutions for problems affecting condenser performance were
suggested
The research concluded that:
• Condenser performance monitoring and diagnostic system needs to be
updated.
• Install of a cathodic protection device is necessary to prevent condenser
tube and tubesheet corrosion.
• Install of a backwash system for the condenser is important to prevent
condenser tube fouling.
Description
Keywords
Problems,Affecting,Condenser,Performance,Dr. Sherief Power